Search icon

Infinity Stone Inc

Branch
Date of last update: 07 Apr 2025. Data updated weekly.

Company Details

Entity Name: Infinity Stone Inc
Jurisdiction: Connecticut
Legal type: Stock
Citizenship: Foreign
Status: Active
Sub status: Annual report due
Date Formed: 14 Aug 2024
Branch of: Infinity Stone Inc, NEW YORK (Company Number 6798418)
Business ALEI: 3053273
Annual report due: 14 Aug 2025
Business address: 13 Columbus Ave, MOUNT KISCO, NY, 10549, United States
Mailing address: 13 Columbus Ave, MOUNT KISCO, NY, United States, 10549
Place of Formation: NEW YORK
E-Mail: michael@infinitysba.com

Industry & Business Activity

NAICS

238990 All Other Specialty Trade Contractors

This industry comprises establishments primarily engaged in specialized trades (except foundation, structure, and building exterior contractors; building equipment contractors; building finishing contractors; and site preparation contractors). The specialty trade work performed includes new work, additions, alterations, maintenance, and repairs. Learn more at the U.S. Census Bureau

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
INFINITY STONE INC 401(K) PROFIT SHARING PLAN & TRUST 2023 471359777 2024-07-29 INFINITY STONE INC 14
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2022-01-01
Business code 237990
Sponsor’s telephone number 2035759484
Plan sponsor’s address 1261 MERIDEN RD BLDG 3, WOLCOTT, CT, 06716

Signature of

Role Plan administrator
Date 2024-07-29
Name of individual signing EDWARD ROJAS
Valid signature Filed with authorized/valid electronic signature
INFINITY STONE INC 401(K) PROFIT SHARING PLAN & TRUST 2022 471359777 2023-05-04 INFINITY STONE INC 15
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2022-01-01
Business code 237990
Sponsor’s telephone number 2035759484
Plan sponsor’s address 1261 MERIDEN RD BLDG 3, WOLCOTT, CT, 06716

Signature of

Role Plan administrator
Date 2023-05-04
Name of individual signing EDWARD ROJAS
Valid signature Filed with authorized/valid electronic signature

Agent

Name Role Business address
Secretary of State Agent 165 Capitol Ave., P.O. BOX 150470, Hartford, CT, 06115-0470, United States

Officer

Name Role Business address Residence address
Michael Amendola Officer 13 Columbus Ave, MOUNT KISCO, NY, 10549, United States 80 Pines Bridge Rd, Mount Kisco, NY, 10549-4112, United States

Filing

Filing number Filing date Effective date Filing category Filing type Report year
BF-0012728252 2024-08-14 - Business Registration Certificate of Authority -

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341008787 0111500 2015-10-22 1261 MERIDEN ROAD, WATERBURY, CT, 06705
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2015-11-10
Emphasis L: FORKLIFT
Case Closed 2019-01-16

Related Activity

Type Complaint
Activity Nr 1030984
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2015-12-02
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. WORKSHOP: The pump hose, ran from the eastern side to the western side of the workshop was creating a tripping hazard for the employees. ABATED DURING THE INSPECTION.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100022 A02
Issuance Date 2015-12-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(2): The floor of every workroom shall be maintained in a clean and, so far as possible, a dry condition. Where wet processes are used, drainage shall be maintained, and false floors, platforms, mats, or other dry standing places should be provided where practicable. WORKSHOP: The floor surface, between the trough/grates and the equipment had an accumulation of water due to water over flowing from the drainage trough on the floor. ABATED DURING THE INSPECTION.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100132 D01
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). WORKSHOP: The employer had not assessed the workplace to determine the necessitate and appropriate types of personal protective equipment (PPE) for the employees.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100132 F01
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(f)(1): The employer shall provide training to each employee who is required by this section to use PPE. WORKSHOP: The employees, required to ear PPE were not provided with training and information on the Personal Protective Equipment (PPE) hazard assessment.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100178 A04
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly. WORKSHOP: The placard of the Mitsubishi powered industrial truck (PIT) that was equipped with a non-factory installed front-end attachment was not changed accordingly.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100178 A05
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(a)(5): If the truck is equipped with front-end attachments other than factory installed attachments, the user shall request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered. WORKSHOP: The employer did not request the manufacturer and went through proper steps and procedures prior to operating the Mitsubishi forklift with a non-factory installed front-end attachment.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 1100.0
Initial Penalty 2000.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). WORKSHOP: The employer did not ensure through providing successful training and evaluation that the operators are competent to operate the powered industrial truck (PIT) safely at all times.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 1100.0
Initial Penalty 2000.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. WORKSHOP: The employer had not established and implemented a site specific hazardous energy control lockout/tagout program consisting of machine specific step-by-step written procedures and employee training for the employees during servicing and maintenance of equipment, such as (but not limited to) polishing machine, CNC, automatic saw.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. WORKSHOP: The employer had not established and implemented step-by-step written energy control procedures in the machine specific for the employees during servicing and maintenance of equipment, such as (but not limited to) the polishing machine, CNC, automatic saw.
Citation ID 01005C
Citaton Type Serious
Standard Cited 19100147 C07 I
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. WORKSHOP: The employees, as affected and other types, were not provided with training and information in the controlling of potentially hazardous and unexpected releases of revised energy sources (lo/to) during servicing and maintenance of equipment, such as (but not limited to) the polishing machine, CNC, automatic saw.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100305 G01
Issuance Date 2015-12-02
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2015-12-15
Nr Instances 2
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(D): Use of flexible cords and cables. Flexible cords and cables shall not be attached to building surfaces: WORKSHOP: 1. The flexible cord of the polishing machine monitor traveled from the wall outlet, wrapped around the electrical piping twice, traveled overhead to another electrical piping and then to the polishing machine monitor. ABATED DURING THE INSPECTION. 2. The orange extension cord, used power the pump traveled from the wall outlet, went through to the floor, looped in front of the polishing machine, wrapped and looped around a work table/leg and then to the pump. ABATED DURING THE INSPECTION
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2015-12-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. WORKSHOP: The outer sheathing of the orange extension cord of the pump was pulled away from the socket. ABATED DURING THE INSPECTION.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met. WORKSHOP: The employer had not established and implemented a written hazard communication program where employees were required to work with chemicals, such as (but not limited to) iron out rust stain remover, and chlorox.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2015-12-02
Abatement Due Date 2016-03-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-12-15
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and material safety data sheets. WORKSHOP: The employer had not trained the employees on hazard communication program where employees were required to work with chemicals, such as (but not limited to) iron out rust stain remover, and chlorox.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
2843737205 2020-04-16 0156 PPP 1261 MERIDEN RD STE 3, WOLCOTT, CT, 06705
Loan Status Date 2021-03-23
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 189682
Loan Approval Amount (current) 189682
Undisbursed Amount 0
Franchise Name -
Lender Location ID 48270
Servicing Lender Name JPMorgan Chase Bank, National Association
Servicing Lender Address 1111 Polaris Pkwy, COLUMBUS, OH, 43240-2031
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address WOLCOTT, NEW HAVEN, CT, 06705-0001
Project Congressional District CT-05
Number of Employees 18
NAICS code 327120
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 194093
Originating Lender Name JPMorgan Chase Bank, National Association
Originating Lender Address CHICAGO, IL
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 190878.9
Forgiveness Paid Date 2021-02-12
1070448505 2021-02-18 0156 PPS 1261 Meriden Rd Ste 3, Wolcott, CT, 06705-3637
Loan Status Date 2022-08-16
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 189682
Loan Approval Amount (current) 189682
Undisbursed Amount 0
Franchise Name -
Lender Location ID 48270
Servicing Lender Name JPMorgan Chase Bank, National Association
Servicing Lender Address 1111 Polaris Pkwy, COLUMBUS, OH, 43240-2031
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Wolcott, NEW HAVEN, CT, 06705-3637
Project Congressional District CT-05
Number of Employees 25
NAICS code 327120
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 48270
Originating Lender Name JPMorgan Chase Bank, National Association
Originating Lender Address COLUMBUS, OH
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 192196.66
Forgiveness Paid Date 2022-06-22
See something incorrect or outdated? Let us know

Sources: Company Profile on Connecticut's Official State Website

* While we strive to keep this information correct and up-to-date, it is not the primary source, and the dataset source should always be referred to for definitive information