Search icon

THE ZELCO GROUP LLC

Company Details

Entity Name: THE ZELCO GROUP LLC
Jurisdiction: Connecticut
Legal type: LLC
Citizenship: Domestic
Status: Active
Sub status: Annual report due
Date Formed: 26 Jul 2024
Business ALEI: 3044261
Annual report due: 31 Mar 2025
NAICS code: 236118 - Residential Remodelers
Business address: 886 Orange Center Rd, Orange, CT, 06477-1730, United States
Mailing address: 886 Orange Center Rd, Orange, CT, United States, 06477-1730
ZIP code: 06477
County: New Haven
Place of Formation: CONNECTICUT
E-Mail: jose@ips-ins.com

Agent

Name Role Business address Mailing address Phone E-Mail Residence address
JOSE ERNESTO CAMPOS-CALIX Agent 886 Orange Center Rd, Orange, CT, 06477-1730, United States 886 Orange Center Rd, Orange, CT, 06477-1730, United States +1 203-804-4080 jose@ips-ins.com 422 Rob Roy Ln, West Haven, CT, 06516-7906, United States

Officer

Name Role Business address Residence address
FABRICIO ZELAYA Officer 886 Orange Center Rd, Orange, CT, 06477-1730, United States 886 Orange Center Rd, Orange, CT, 06477-1730, United States

Filing

Filing number Filing date Effective date Filing category Filing type Report year
BF-0012704063 2024-07-26 No data Business Formation Certificate of Organization No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342354784 0111500 2017-04-19 100 LAUREL STREET, WEST HAVEN, CT, 06516
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-04-19
Emphasis L: FALL, L: RESCON
Case Closed 2019-02-25

Related Activity

Type Referral
Activity Nr 1219721
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2017-06-09
Abatement Due Date 2017-07-06
Current Penalty 1850.0
Initial Penalty 2716.0
Final Order 2017-07-18
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Jobsite: The pump jack scaffold from that the employees were working was not inspected daily for visible defects by a competent person.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2017-06-09
Abatement Due Date 2017-07-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-07-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. Jobsite: The pump jack scaffold from that the employees were working was erected and used within 4 feet of exposed and energized power lines.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2017-06-09
Abatement Due Date 2017-07-06
Current Penalty 1850.0
Initial Penalty 2716.0
Final Order 2017-07-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Jobsite: The pump jack scaffold from that the employees were working was not erected under the supervision of a competent person in scaffold erection.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2017-06-09
Abatement Due Date 2017-06-15
Current Penalty 1850.0
Initial Penalty 2716.0
Final Order 2017-07-18
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Jobsite: The employees who were working from the pump jack scaffold were not protected from fall hazards by the use of guardrails or personal fall arrest systems.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-06-09
Abatement Due Date 2017-07-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-07-18
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Jobsite: The employee who was engaged in residential construction activities on the porch roof was not protected from fall hazards by the use guardrails, safety nets or personal fall arrest systems.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260454 A01
Issuance Date 2017-06-09
Abatement Due Date 2017-07-06
Current Penalty 1450.0
Initial Penalty 2173.0
Final Order 2017-07-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area. Jobsite: The employer did not ensure that the employees who were working from the pump jack scaffold were trained to recognize the hazards associated with the type of scaffold being used.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260454 B01
Issuance Date 2017-06-09
Abatement Due Date 2017-07-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-07-18
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b)(1): The employer did not have each employee who is involved in erecting, disassembling, moving, operating, maintaining, or inspecting a scaffold trained by a competent person to recognize the hazards associated with the work in question. Jobsite: The employees that were involved in erecting, maintaining and inspecting the pump jack scaffold were not trained by a competent person to recognize any hazards associated with the work in question.

Date of last update: 10 Mar 2025