Entity Name: | M&L General Contractor LLC |
Jurisdiction: | Connecticut |
Legal type: | LLC |
Citizenship: | Domestic |
Status: | Active |
Sub status: | Annual report due |
Date Formed: | 07 Jul 2023 |
Business ALEI: | 2818281 |
Annual report due: | 31 Mar 2026 |
Business address: | 16 Reuven Dr, Ledyard, CT, 06339-1315, United States |
Mailing address: | 16 Reuven Dr, Ledyard, CT, United States, 06339-1315 |
ZIP code: | 06339 |
County: | New London |
Place of Formation: | CONNECTICUT |
E-Mail: | luismendez9387@gmail.com |
NAICS
236115 New Single-Family Housing Construction (except For-Sale Builders)This U.S. industry comprises general contractor establishments primarily responsible for the entire construction of new single-family housing, such as single-family detached houses and town houses or row houses where each housing unit (1) is separated from its neighbors by a ground-to-roof wall and (2) has no housing units constructed above or below. This industry includes general contractors responsible for the on-site assembly of modular and prefabricated houses. Single-family housing design-build firms and single-family construction management firms acting as general contractors are included in this industry. Learn more at the U.S. Census Bureau
Name | Role | Business address | Phone | Residence address | |
---|---|---|---|---|---|
Luis Mendez | Officer | 16 Reuven Dr, Ledyard, CT, 06339-1315, United States | +1 860-326-9387 | luismendez9387@gmail.com | 16 Reuven Dr, Ledyard, CT, 06339-1315, United States |
Name | Role | Business address | Mailing address | Phone | Residence address | |
---|---|---|---|---|---|---|
Luis Mendez | Agent | 16 Reuven Dr, Ledyard, CT, 06339-1315, United States | 16 Reuven Dr, Ledyard, CT, 06339-1315, United States | +1 860-326-9387 | luismendez9387@gmail.com | 16 Reuven Dr, Ledyard, CT, 06339-1315, United States |
Credential | Credential type | Status | Status reason | Issue date | Effective date | Expiration date |
---|---|---|---|---|---|---|
HIC.0670109 | HOME IMPROVEMENT CONTRACTOR | ACTIVE | CURRENT | 2023-07-11 | 2024-04-01 | 2025-03-31 |
Filing number | Filing date | Effective date | Filing category | Filing type | Report year |
---|---|---|---|---|---|
BF-0012829234 | 2025-02-24 | - | Annual Report | Annual Report | - |
BF-0012438207 | 2024-03-28 | - | Annual Report | Annual Report | - |
BF-0011877088 | 2023-07-07 | - | Business Formation | Certificate of Organization | - |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347536534 | 0112000 | 2024-06-07 | 122 BOSTON POST RD, WATERFORD, CT, 06385 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2196483 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2024-09-26 |
Abatement Due Date | 2024-11-14 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2024-10-23 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were likely to cause death or serious physical harm to employees from exposure to fall hazards by using the forks of a rough terrain forklift as a work platform without any fall protection or other safety precautions in place. 122 Boston Post Road, Waterford, CT. On or about June 7, 2024: a) Employees were elevated approximately 25 feet above ground level on the forks of a Lull 844C-42 Rough Terrain Forklift Truck in order to conduct framing activities on the peak of a dormer. The employees were not provided with fall protection and were not otherwise elevated in a manner consistent with the requirements of ANSI B56.6 Section 5.15.1. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260028 A |
Issuance Date | 2024-09-26 |
Current Penalty | 2765.0 |
Initial Penalty | 2765.0 |
Final Order | 2024-10-23 |
Nr Instances | 3 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: 122 Boston Post Road Waterford, CT. On or about June 7, 2024 employees were not wearing appropriate personal protective equipment under the following conditions while conducting framing activities: a) No head protection worn by employees working on the ground level and exposed to falling object hazards from those working on the roof above them. b) No eye protection worn by employees exposed to flying object hazards from the use of using pneumatic nailers, hammers, and cordless electric drill/ drivers. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2024-09-26 |
Current Penalty | 3457.0 |
Initial Penalty | 3457.0 |
Final Order | 2024-10-23 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: 122 Boston Post Road Waterford, CT: On or about June 7, 2024 employees engaged in framing activities on a 12-12 pitch roof at heights varying from 15 to 25 feet above ground level were not protected by any guardrail systems, personal fall arrest, or alternative fall protection measures. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2024-09-26 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-10-23 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: 122 Boston Post Road Waterford, CT. On or about June 7, 2024 the employer did not provide training to their employees in PPE selection, use, or hazard recognition for framing activities. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-09-26 |
Abatement Due Date | 2024-11-14 |
Current Penalty | 3457.0 |
Initial Penalty | 3457.0 |
Final Order | 2024-10-23 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: 122 Boston Post Road Waterford, CT: On or about June 7, 2024 the side rails of a portable extension ladder used to access and egress a 12-12 pitch roof did not extend at least three feet above the surface being accessed. |