Search icon

M&L General Contractor LLC

Date of last update: 07 Apr 2025. Data updated weekly.

Company Details

Entity Name: M&L General Contractor LLC
Jurisdiction: Connecticut
Legal type: LLC
Citizenship: Domestic
Status: Active
Sub status: Annual report due
Date Formed: 07 Jul 2023
Business ALEI: 2818281
Annual report due: 31 Mar 2026
Business address: 16 Reuven Dr, Ledyard, CT, 06339-1315, United States
Mailing address: 16 Reuven Dr, Ledyard, CT, United States, 06339-1315
ZIP code: 06339
County: New London
Place of Formation: CONNECTICUT
E-Mail: luismendez9387@gmail.com

Industry & Business Activity

NAICS

236115 New Single-Family Housing Construction (except For-Sale Builders)

This U.S. industry comprises general contractor establishments primarily responsible for the entire construction of new single-family housing, such as single-family detached houses and town houses or row houses where each housing unit (1) is separated from its neighbors by a ground-to-roof wall and (2) has no housing units constructed above or below. This industry includes general contractors responsible for the on-site assembly of modular and prefabricated houses. Single-family housing design-build firms and single-family construction management firms acting as general contractors are included in this industry. Learn more at the U.S. Census Bureau

Officer

Name Role Business address Phone E-Mail Residence address
Luis Mendez Officer 16 Reuven Dr, Ledyard, CT, 06339-1315, United States +1 860-326-9387 luismendez9387@gmail.com 16 Reuven Dr, Ledyard, CT, 06339-1315, United States

Agent

Name Role Business address Mailing address Phone E-Mail Residence address
Luis Mendez Agent 16 Reuven Dr, Ledyard, CT, 06339-1315, United States 16 Reuven Dr, Ledyard, CT, 06339-1315, United States +1 860-326-9387 luismendez9387@gmail.com 16 Reuven Dr, Ledyard, CT, 06339-1315, United States

License

Credential Credential type Status Status reason Issue date Effective date Expiration date
HIC.0670109 HOME IMPROVEMENT CONTRACTOR ACTIVE CURRENT 2023-07-11 2024-04-01 2025-03-31

Filing

Filing number Filing date Effective date Filing category Filing type Report year
BF-0012829234 2025-02-24 - Annual Report Annual Report -
BF-0012438207 2024-03-28 - Annual Report Annual Report -
BF-0011877088 2023-07-07 - Business Formation Certificate of Organization -

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347536534 0112000 2024-06-07 122 BOSTON POST RD, WATERFORD, CT, 06385
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-06-07
Emphasis L: FORKLIFT, N: FALL

Related Activity

Type Referral
Activity Nr 2196483
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2024-09-26
Abatement Due Date 2024-11-14
Current Penalty 4839.0
Initial Penalty 4839.0
Final Order 2024-10-23
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were likely to cause death or serious physical harm to employees from exposure to fall hazards by using the forks of a rough terrain forklift as a work platform without any fall protection or other safety precautions in place. 122 Boston Post Road, Waterford, CT. On or about June 7, 2024: a) Employees were elevated approximately 25 feet above ground level on the forks of a Lull 844C-42 Rough Terrain Forklift Truck in order to conduct framing activities on the peak of a dormer. The employees were not provided with fall protection and were not otherwise elevated in a manner consistent with the requirements of ANSI B56.6 Section 5.15.1.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260028 A
Issuance Date 2024-09-26
Current Penalty 2765.0
Initial Penalty 2765.0
Final Order 2024-10-23
Nr Instances 3
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: 122 Boston Post Road Waterford, CT. On or about June 7, 2024 employees were not wearing appropriate personal protective equipment under the following conditions while conducting framing activities: a) No head protection worn by employees working on the ground level and exposed to falling object hazards from those working on the roof above them. b) No eye protection worn by employees exposed to flying object hazards from the use of using pneumatic nailers, hammers, and cordless electric drill/ drivers.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2024-09-26
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-10-23
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: 122 Boston Post Road Waterford, CT: On or about June 7, 2024 employees engaged in framing activities on a 12-12 pitch roof at heights varying from 15 to 25 feet above ground level were not protected by any guardrail systems, personal fall arrest, or alternative fall protection measures.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-09-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-10-23
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: 122 Boston Post Road Waterford, CT. On or about June 7, 2024 the employer did not provide training to their employees in PPE selection, use, or hazard recognition for framing activities.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-09-26
Abatement Due Date 2024-11-14
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-10-23
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: 122 Boston Post Road Waterford, CT: On or about June 7, 2024 the side rails of a portable extension ladder used to access and egress a 12-12 pitch roof did not extend at least three feet above the surface being accessed.
See something incorrect or outdated? Let us know

Sources: Company Profile on Connecticut's Official State Website

* While we strive to keep this information correct and up-to-date, it is not the primary source, and the dataset source should always be referred to for definitive information