Entity Name: | AVILES REMODEL LLC |
Jurisdiction: | Connecticut |
Legal type: | LLC |
Citizenship: | Domestic |
Status: | Active |
Sub status: | Annual report past due |
Date Formed: | 16 Jan 2021 |
Business ALEI: | 1373904 |
Annual report due: | 31 Mar 2025 |
Business address: | 230 Blakeslee St, Bristol, CT, 06010-6329, United States |
Mailing address: | 230 Blakeslee St, APT 5, Bristol, CT, United States, 06010-6329 |
ZIP code: | 06010 |
County: | Hartford |
Place of Formation: | CONNECTICUT |
E-Mail: | ALVAROAVILESAA.50@GMAIL.COM |
NAICS
238990 All Other Specialty Trade ContractorsThis industry comprises establishments primarily engaged in specialized trades (except foundation, structure, and building exterior contractors; building equipment contractors; building finishing contractors; and site preparation contractors). The specialty trade work performed includes new work, additions, alterations, maintenance, and repairs. Learn more at the U.S. Census Bureau
Name | Role | Business address | Phone | Residence address | |
---|---|---|---|---|---|
ALVARO AVILES AREVALO | Officer | 230 Blakeslee St, Bristol, CT, 06010-6329, United States | +1 203-218-7430 | alvaroavilesaa.50@gmail.com | 230 Blakeslee St, Bristol, CT, 06010-6329, United States |
Name | Role | Business address | Mailing address | Phone | Residence address | |
---|---|---|---|---|---|---|
ALVARO AVILES AREVALO | Agent | 230 Blakeslee St, Bristol, CT, 06010-6329, United States | 230 Blakeslee St, Bristol, CT, 06010-6329, United States | +1 203-218-7430 | alvaroavilesaa.50@gmail.com | 230 Blakeslee St, Bristol, CT, 06010-6329, United States |
Credential | Credential type | Status | Status reason | Issue date | Effective date | Expiration date |
---|---|---|---|---|---|---|
HIC.0668301 | HOME IMPROVEMENT CONTRACTOR | ACTIVE | CURRENT | 2023-01-20 | 2024-04-01 | 2025-03-31 |
Filing number | Filing date | Effective date | Filing category | Filing type | Report year |
---|---|---|---|---|---|
BF-0012336627 | 2024-02-15 | - | Annual Report | Annual Report | - |
BF-0011095259 | 2023-05-08 | - | Annual Report | Annual Report | - |
BF-0010367670 | 2022-08-12 | - | Annual Report | Annual Report | 2022 |
0007066900 | 2021-01-16 | 2021-01-16 | Business Formation | Certificate of Organization | - |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346824030 | 0112000 | 2023-07-11 | 4 HAZELNUT DRIVE, FARMINGTON, CT, 06030 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2052840 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2023-12-04 |
Current Penalty | 1250.0 |
Initial Penalty | 2419.0 |
Final Order | 2024-01-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system. 4 Hazelnut Drive, Farmington, Connecticut Chimney repair project: On or about July 11, 2023, and at times prior thereto, employees were exposed to a fall hazard of approximately 10 feet while performing chimney repair activities on a 10/12 pitch roof without fall protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2023-12-04 |
Current Penalty | 1250.0 |
Initial Penalty | 1935.0 |
Final Order | 2024-01-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: 4 Hazelnut Drive, Farmington, Connecticut Chimney repair project: On or about July 11, 2023, and at times prior thereto, employees were using the following extension ladder to access the roof: A. The ladder in use extended to .5 feet not meeting the minimum 3 feet past the landing exposing them to a fall hazard of approximately 10 feet. |
Inspection Type | Planned |
Scope | NoInspection |
Safety/Health | Safety |
Close Conference | 2022-07-21 |
Emphasis | L: FALL, L: RESCON, P: FALL |
Case Closed | 2022-07-27 |
Related Activity
Type | Complaint |
Activity Nr | 1922201 |
Safety | Yes |
Sources: Company Profile on Connecticut's Official State Website
* While we strive to keep this information correct and up-to-date, it is not the primary source, and the dataset source should always be referred to for definitive information