Entity Name: | FORCE HOME IMPROVEMENT LLC |
Jurisdiction: | Connecticut |
Legal type: | LLC |
Citizenship: | Domestic |
Status: | Active |
Sub status: | Annual report due |
Date Formed: | 08 Nov 2017 |
Business ALEI: | 1254964 |
Annual report due: | 31 Mar 2025 |
Business address: | 120 WASHINGTON ST, WALLINGFORD, CT, 06492, United States |
Mailing address: | 120 WASHINGTON ST, WALLINGFORD, CT, United States, 06492 |
ZIP code: | 06492 |
County: | New Haven |
Place of Formation: | CONNECTICUT |
E-Mail: | forcehicompany@gmail.com |
NAICS
236118 Residential RemodelersThis U.S. industry comprises establishments primarily responsible for the remodeling construction (including additions, alterations, reconstruction, maintenance, and repairs) of houses and other residential buildings, single-family and multifamily. Included in this industry are remodeling general contractors, for-sale remodelers, remodeling design-build firms, and remodeling project construction management firms. Learn more at the U.S. Census Bureau
Name | Role | Business address | Mailing address | Phone | Residence address | |
---|---|---|---|---|---|---|
ALEJANDRO RUIZ-GARCIA | Agent | 120 WASHINGTON ST, WALLINGFORD, CT, 06492, United States | 120 WASHINGTON ST, WALLINGFORD, CT, 06492, United States | +1 203-600-4894 | forcehicompany@gmail.com | 120 WASHINGTON ST, WALLINGFORD, CT, 06492, United States |
Name | Role | Business address | Phone | Residence address | |
---|---|---|---|---|---|
ALEJANDRO RUIZ-GARCIA | Officer | 120 WASHINGTON ST, WALLINGFORD, CT, 06492, United States | +1 203-600-4894 | forcehicompany@gmail.com | 120 WASHINGTON ST, WALLINGFORD, CT, 06492, United States |
Credential | Credential type | Status | Status reason | Issue date | Effective date | Expiration date |
---|---|---|---|---|---|---|
HIC.0650029 | HOME IMPROVEMENT CONTRACTOR | ACTIVE | CURRENT | 2017-11-17 | 2024-04-10 | 2025-03-31 |
Filing number | Filing date | Effective date | Filing category | Filing type | Report year |
---|---|---|---|---|---|
BF-0012570914 | 2024-04-09 | - | Annual Report | Annual Report | - |
BF-0011345805 | 2023-05-24 | - | Annual Report | Annual Report | - |
BF-0010628431 | 2023-02-07 | - | Annual Report | Annual Report | - |
BF-0009889111 | 2022-05-26 | - | Annual Report | Annual Report | - |
BF-0008850838 | 2022-05-26 | - | Annual Report | Annual Report | 2020 |
0006717068 | 2020-01-09 | - | Annual Report | Annual Report | 2018 |
0006717076 | 2020-01-09 | - | Annual Report | Annual Report | 2019 |
0005962903 | 2017-11-08 | 2017-11-08 | Business Formation | Certificate of Organization | - |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347394603 | 0111500 | 2024-04-05 | 367 MAIN STREET #27, OLD SAYBROOK, CT, 06475 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2148562 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-08-06 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2024-09-04 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR1926.501(b)(13): Employees engaged in residential construction activities 6 feet or more above lower levels were not protected by guardrail systems, safety net systems, or personal fall arrest systems. Worksite: On or about April 5, 2024, employees were exposed to fall hazards due to working on a residential roof, approximately 15 feet without fall protection. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-08-06 |
Current Penalty | 3457.0 |
Initial Penalty | 3457.0 |
Final Order | 2024-09-04 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. Worksite: On or about April 5, 2024, employees were exposed to a fall hazard of approximately 9 feet due to ladder side rails not extended above the upper landing surface to gain access to the garage roof. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19261053 B05 I |
Issuance Date | 2024-08-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-09-04 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). Worksite: On or about April 5, 2024, employees were exposed to a fall hazard of approximately 9 feet due to using a ladder that was not properly placed one-quarter of the working height of the ladder from the base of the building. The working height was 9 feet and the butt of the ladder was measured 6 feet from the base of the building. |
Sources: Connecticut's Official State Website
* While we strive to keep this information correct and up-to-date, it is not the primary source, and the dataset source should always be referred to for definitive information