Search icon

JUAN ACERO CONSTRUCTION LLC

Date of last update: 28 Apr 2025. Data updated weekly.

Company Details

Entity Name: JUAN ACERO CONSTRUCTION LLC
Jurisdiction: Connecticut
Legal type: LLC
Citizenship: Domestic
Status: Active
Sub status: Annual report past due
Date Formed: 28 Apr 2014
Business ALEI: 1140515
Annual report due: 31 Mar 2026
Business address: 37 Beaver ST Apt 1, Danbury, CT, 06810, United States
Mailing address: 37 Beaver ST Apt 1, Danbury, CT, United States, 06810
ZIP code: 06810
County: Fairfield
Place of Formation: CONNECTICUT
E-Mail: RMINSURANCE@SBCGLOBAL.NET

Industry & Business Activity

NAICS

238130 Framing Contractors

This industry comprises establishments primarily engaged in structural framing and sheathing using materials other than structural steel or concrete. The work performed may include new work, additions, alterations, maintenance, and repairs. Learn more at the U.S. Census Bureau

Officer

Name Role Business address Residence address
JUAN JOSE ACERO PICHAZACA Officer 37 Beaver ST Apt 1, Danbury, CT, 06810, United States 37 Beaver ST Apt 1, Danbury, CT, 06810, United States

Agent

Name Role Business address Mailing address Phone E-Mail Residence address
JUAN JOSE ACERO PICHASACA Agent 37 Beaver ST Apt 1, Danbury, CT, 06810, United States 37 Beaver ST Apt 1, Danbury, CT, 06810, United States +1 203-648-8296 RMINSURANCE@SBCGLOBAL.NET 37 BEAVER ST 1ST FL, DANBURY, CT, 06810, United States

License

Credential Credential type Status Status reason Issue date Effective date Expiration date
HIC.0642896 HOME IMPROVEMENT CONTRACTOR ACTIVE CURRENT 2015-05-29 2024-04-18 2025-03-31

Filing

Filing number Filing date Effective date Filing category Filing type Report year
BF-0013036329 2025-02-28 - Annual Report Annual Report -
BF-0012335895 2025-02-28 - Annual Report Annual Report -
BF-0011322671 2023-05-10 - Annual Report Annual Report -
BF-0010569776 2022-08-17 - Annual Report Annual Report -
BF-0009704946 2022-04-14 - Annual Report Annual Report 2018
BF-0009704945 2022-04-14 - Annual Report Annual Report 2019
BF-0009950930 2022-04-14 - Annual Report Annual Report -
BF-0009704947 2022-04-14 - Annual Report Annual Report 2017
BF-0009704948 2022-04-14 - Annual Report Annual Report 2020
0006826916 2020-03-11 - Annual Report Annual Report 2016

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342273331 0111500 2017-04-24 107-109 CHERRY CIRCLE LANE, PROSPECT, CT, 06712
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-04-24
Emphasis L: RESCON, L: FALL, P: RESCON
Case Closed 2022-03-16

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2017-05-24
Current Penalty 2050.0
Initial Penalty 2988.0
Final Order 2017-06-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee. Worksite: The single anchorage point that was used to attach the employees personal fall arrest system was not installed in a manner that would support at least 5000 pounds.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2017-05-24
Current Penalty 5800.0
Initial Penalty 8366.0
Final Order 2017-06-16
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b). Worksite: The employer did not ensure that the employee who was engaged in residential construction activities from the residential roof was protected from fall hazards above 6 feet by the use of guardrails, safety nets or a personal fall arrest system. Juan Acero Construction, LLC was previously cited for a violation of this Occupational Safety and Health standard 29 CFR 1926.501(b)(13) which was contained in OSHA Inspection Number 1015425, Citation Number 1, Item Number 2a, issued on 02/23/2015 with respect to a workplace located at Oak Branch Drive, Building 9, Brookfield, CT and became a final order on 10/02/2015.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260503 A01
Issuance Date 2017-05-24
Abatement Due Date 2017-06-20
Current Penalty 4150.0
Initial Penalty 5976.0
Final Order 2017-06-16
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. Worksite: The employer did not ensure that the employee who was exposed to fall hazards while engaged in residential construction activities from the roof at a height above 6 feet was trained in fall hazards and the procedures to be followed to minimize such hazards. \ Juan Acero Construction, LLC was previously cited for a violation of this Occupational Safety and Health standard 29 CFR 1926.503(a)(1) which was contained in OSHA Inspection Number 1015425, Citation Number 1, Item Number 2b, issued on 2/23/2015 with respect to a workplace located at Oak Branch Drive, Building 9, Brookfield, CT and became a final order on 10/02/2015.
340154251 0111500 2014-12-04 OAK BRANCH DRIVE BUILDING 9, BROOKFIELD, CT, 06804
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2014-12-04
Emphasis L: FALL, L: EISAX30, L: EISAOF
Case Closed 2018-02-22

Related Activity

Type Inspection
Activity Nr 1015577
Safety Yes
Type Referral
Activity Nr 928691
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260025 A
Issuance Date 2015-02-23
Abatement Due Date 2015-03-03
Current Penalty 1120.0
Initial Penalty 1600.0
Final Order 2015-10-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form or scrap lumber with protruding nails was not kept clear from work areas: Location: Oak Branch Drive, Building 9, Brookfield, CT Protruding nails were present on the walking and working surface of the residential pitched roof.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-02-23
Abatement Due Date 2015-03-03
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2015-10-02
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: Oak Branch Drive, Building 9, Brookfield, CT An adequate fall protection system was not being utilized on the steep pitch roof, with an eve to ground height of approximately 29 feet 2 inches, while employees were performing roofing work.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-02-23
Abatement Due Date 2015-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-10-02
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Location: Oak Branch Drive, Building 9, Brookfield, CT The employer did not ensure that all employees had been adequately trained in the hazards associated with falling and the proper ways and procedures to take in order to minimize and/or eliminate those hazards.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2015-02-23
Abatement Due Date 2015-03-05
Current Penalty 1400.0
Initial Penalty 2000.0
Final Order 2015-10-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Location: Oak Branch Drive, Building 9, Brookfield, CT The Werner 40 foot aluminum extension ladder did not extend at least three feet above the upper landing surface of the roof.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2015-02-23
Abatement Due Date 2015-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-10-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. Location: Oak Branch Drive, Building 9, Brookfield, CT The employer did not ensure that all employees had been adequately trained in the hazards associated with ladders and the proper ways and procedures to take in order to minimize the hazards.
See something incorrect or outdated? Let us know

Sources: Company Profile on Connecticut's Official State Website

* While we strive to keep this information correct and up-to-date, it is not the primary source, and the dataset source should always be referred to for definitive information