Entity Name: | BEST CONNECTICUT ROOFING LLC |
Jurisdiction: | Connecticut |
Legal type: | LLC |
Citizenship: | Domestic |
Status: | Active |
Sub status: | Annual report past due |
Date Formed: | 07 Mar 2011 |
Business ALEI: | 1031034 |
Annual report due: | 31 Mar 2024 |
NAICS code: | 238160 - Roofing Contractors |
Business address: | 35 Meridian St, Meriden, CT, 06451-5515, United States |
Mailing address: | 35 Meridian St, Meriden, CT, United States, 06451-5515 |
ZIP code: | 06451 |
County: | New Haven |
Place of Formation: | CONNECTICUT |
E-Mail: | bestconnecticutroofing@hotmail.com |
Name | Role | Business address | Phone | Residence address | |
---|---|---|---|---|---|
JOSE CUSNIA | Officer | 81 PARKER NORTH AVENUE, MERIDEN, CT, 06450, United States | +1 203-442-4165 | bestconnecticutroofing@hotmail.com | 35 meridian st, MERIDEN, CT, 06451, United States |
Name | Role | Business address | Mailing address | Phone | Residence address | |
---|---|---|---|---|---|---|
JOSE CUSNIA | Agent | 35 Meridian St, Meriden, CT, 06451-5515, United States | 35 Meridian St, Meriden, CT, 06451-5515, United States | +1 203-442-4165 | bestconnecticutroofing@hotmail.com | 35 meridian st, MERIDEN, CT, 06451, United States |
Filing number | Filing date | Effective date | Filing category | Filing type | Report year |
---|---|---|---|---|---|
BF-0011186487 | 2023-03-09 | No data | Annual Report | Annual Report | No data |
BF-0010008249 | 2022-07-23 | No data | Annual Report | Annual Report | No data |
BF-0008702055 | 2022-07-23 | No data | Annual Report | Annual Report | 2018 |
BF-0008702047 | 2022-07-23 | No data | Annual Report | Annual Report | 2017 |
BF-0008702051 | 2022-07-23 | No data | Annual Report | Annual Report | 2016 |
BF-0008702052 | 2022-07-23 | No data | Annual Report | Annual Report | 2020 |
BF-0008702054 | 2022-07-23 | No data | Annual Report | Annual Report | 2014 |
BF-0008702050 | 2022-07-23 | No data | Annual Report | Annual Report | 2019 |
BF-0008702049 | 2022-07-23 | No data | Annual Report | Annual Report | 2015 |
BF-0008702053 | 2022-07-23 | No data | Annual Report | Annual Report | 2012 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345147102 | 0111500 | 2020-12-09 | 35 GOODWILL AVENUE, MERIDEN, CT, 06451 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1728805 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2021-04-14 |
Abatement Due Date | 2021-05-19 |
Current Penalty | 4096.0 |
Initial Penalty | 4096.0 |
Final Order | 2021-06-09 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Jobsite: Each employee working on the approximately 10 in 12 pitch roof with an approximately 22 foot eave to ground fall distance were not protected from fall hazards by the use guardrails, safety nets or personal fall arrest systems. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260502 D17 |
Issuance Date | 2021-04-14 |
Abatement Due Date | 2021-05-19 |
Current Penalty | 2926.0 |
Initial Penalty | 2926.0 |
Final Order | 2021-06-09 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(17):The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head. Jobsite: Fall protection lifeline/lanyard attachment points were located at the center of employee's front torso and not located in the center of the employee's back while working on an approximately 10 in 12 pitched residential roofing with an approximately 22 foot eave to ground fall distance. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2021-04-14 |
Abatement Due Date | 2021-05-19 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-06-09 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Jobsite: Each employee performing roofing work on an approximately 10 in 12 pitched residential type roof with an approximately 22 foot eave to ground fall distance was not provided with a fall protection training program to enable each employee to recognize the hazards of falling and the procedures to minimize/eliminate those hazards. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19030019 C01 |
Issuance Date | 2021-07-29 |
Abatement Due Date | 2021-08-13 |
Current Penalty | 329.0 |
Initial Penalty | 329.0 |
Final Order | 2021-08-27 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1903.19(c)(1): Employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Location: 35 Goodwill Avenue, Meriden, Connecticut Abatement certification and verification for Citation 01, Item 001; Citation 01, Item 002a; and Citation 01, Item 002b with a final order date of 6/9/2021 was not received within 10 calendar days (by 5/29/2021) following the abatement due date (5/19/2021). |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2014-06-16 |
Emphasis | L: FALL, N: CTARGET, P: FALL |
Case Closed | 2018-10-19 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2014-09-24 |
Abatement Due Date | 2014-10-02 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2014-12-12 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. WORKSITE: The employees, performing roofing work on a 3/12 pitch roofs, were not protected from falls between 7-feet 4-inches and 16-feet 4-inches to the ground by the use of appropriate fall protection devices and/or systems. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2011-08-01 |
Emphasis | L: FALL, S: FALL FROM HEIGHT |
Case Closed | 2016-01-07 |
Related Activity
Type | Referral |
Activity Nr | 202632592 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2011-11-02 |
Abatement Due Date | 2011-11-14 |
Current Penalty | 4200.0 |
Initial Penalty | 4200.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260502 D16 III |
Issuance Date | 2011-11-02 |
Abatement Due Date | 2011-11-14 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2011-11-02 |
Abatement Due Date | 2011-11-28 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 05 |