Search icon

NEWMARK MEDICAL COMPONENTS, INC.

Date of last update: 21 Apr 2025. Data updated weekly.

Company Details

Entity Name: NEWMARK MEDICAL COMPONENTS, INC.
Jurisdiction: Connecticut
Legal type: Stock
Citizenship: Domestic
Status: Active
Sub status: Annual report due
Date Formed: 02 Sep 2010
Business ALEI: 1014255
Annual report due: 02 Sep 2025
Business address: 2670 SOUTH MAIN STREET, WATERBURY, CT, 06706, United States
Mailing address: P.O. BOX 1030, WATERBURY, CT, United States, 06706
ZIP code: 06706
County: New Haven
Place of Formation: CONNECTICUT
Total authorized shares: 20000
E-Mail: JGOGGINS@PLATTBROS.COM

Industry & Business Activity

NAICS

332999 All Other Miscellaneous Fabricated Metal Product Manufacturing

This U.S. industry comprises establishments primarily engaged in manufacturing fabricated metal products (except forgings and stampings, cutlery and handtools, architectural and structural metals, boilers, tanks, shipping containers, hardware, spring and wire products, machine shop products, turned products, screws, nuts and bolts, metal valves, ball and roller bearings, ammunition, small arms and other ordnances and accessories, and fabricated pipes and pipe fittings). Learn more at the U.S. Census Bureau

Agent

Name Role Business address Mailing address Phone E-Mail Residence address
David Mieczkowski Agent 2670 SOUTH MAIN STREET, WATERBURY, CT, 06706, United States 2670 SOUTH MAIN STREET, WATERBURY, CT, 06706, United States +1 203-597-7656 dmieczkowski@plattbros.com 82 Judson Ave, Woodbury, CT, 06798-2712, United States

Officer

Name Role Business address Residence address
DAVID W. MIECZKOWSKI Officer 2670 SOUTH MAIN ST, WATERBURY, CT, 06706, United States 82 JUDSON AVE, WOODBURY, CT, 06798, United States
JAMES GOGGINS Officer 2670 SOUTH MAIN STREET, WATERBURY, CT, 06706, United States 115 CHARTER OAK DRIVE, CHESHIRE, CT, 06410, United States

Director

Name Role Business address Residence address
JAMES P. BEHUNIAK Director 2670 SOUTH MAIN STREET, WATERBURY, CT, 06708, United States 88 PADDY HOLLOW ROAD, BETHLEHEM, CT, 06751, United States
DAVID MIECZKOWSKI Director 2670 SOUTH MAIN ST, WATERBURY, CT, 06706, United States 82 JUDSON AVENUE, WOODBURY, CT, 06798, United States

Filing

Filing number Filing date Effective date Filing category Filing type Report year
BF-0012157554 2024-08-05 - Annual Report Annual Report -
BF-0011184509 2023-08-03 - Annual Report Annual Report -
BF-0010339963 2022-08-03 - Annual Report Annual Report 2022
BF-0009812516 2021-10-05 - Annual Report Annual Report -
0006973529 2020-09-04 - Annual Report Annual Report 2020
0006745768 2020-02-04 - Annual Report Annual Report 2019
0006229692 2018-08-09 - Annual Report Annual Report 2018
0006229689 2018-08-09 - Annual Report Annual Report 2017
0005646068 2016-09-07 - Annual Report Annual Report 2016
0005646056 2016-09-07 - Annual Report Annual Report 2015

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343128872 0111500 2018-04-30 2670 SOUTH MAIN STREET, WATERBURY, CT, 06706
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-05-15
Emphasis L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
Case Closed 2018-06-21

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2018-05-21
Current Penalty 3600.0
Initial Penalty 5691.0
Final Order 2018-06-19
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: WORKSHOP: The following rotating collets of the Hardinge lathes were unguarded: 1. Hardinge lathe; Super Precision. 2. Hardinge lathe.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100215 A02
Issuance Date 2018-05-21
Current Penalty 3600.0
Initial Penalty 5691.0
Final Order 2018-06-19
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: WORKSHOP: The flange and spindle end of the Brown & Sharpe surface grinder were unguarded.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100219 E03 I
Issuance Date 2018-05-21
Abatement Due Date 2018-07-09
Current Penalty 3800.0
Initial Penalty 5691.0
Final Order 2018-06-19
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): WORKSHOP: The inclined v-belt of the Brown & Sharpe surface grinder was unguarded.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2018-05-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-19
Nr Instances 1
Nr Exposed 9
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: WORKSHOP: The employer had not verified through a written certification that the Workplace Hazard Assessment for personal protective equipment (PPE) had been performed as complete.
340634260 0111500 2015-05-18 2670 SOUTH MAIN STREET, WATERBURY, CT, 06706
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2015-06-12
Emphasis L: EISAOF, L: EISAX30, N: AMPUTATE
Case Closed 2015-09-02

Related Activity

Type Complaint
Activity Nr 984499
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2015-06-24
Current Penalty 2520.0
Initial Penalty 3600.0
Final Order 2015-07-21
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Point of Operation Guarding. Point of operation is the area on a machine where work is actually performed upon the material being processed. The point of operation of machines whose operation exposes an employee to injury, shall be guarded: WORKSHOP: The points of the operation of the following Perkins eyelet presses were not guarded: 1. Perkins eyelet press #9. ABATED DURING THE INSPECTION 2. Perkins eyelet press #13. ABATED DURING THE INSPECTION
Citation ID 01002
Citaton Type Serious
Standard Cited 19100217 C01 I
Issuance Date 2015-06-24
Current Penalty 3150.0
Initial Penalty 4500.0
Final Order 2015-07-21
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(c)(1)(i): It shall be the responsibility of the employer to provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10. WORKSHOP: The point-of operation of the Federal 22-ton progressive mechanical power press was unguarded. ABATED DURING THE INSPECTION
Citation ID 01003
Citaton Type Serious
Standard Cited 19100219 B01 I
Issuance Date 2015-06-24
Current Penalty 2520.0
Initial Penalty 3600.0
Final Order 2015-07-21
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(b)(1): Flywheels. Flywheels located so that any part is seven (7) feet or less above floor or platform shall be guarded in accordance with the requirements of this subparagraph: (i) With an enclosure of sheet, perforated, or expanded metal, or woven wire; WORKSHOP: The flywheel of the Federal progressive mechanical power press was partially unguarded. ABATED DURING THE INSPECTION