347960007
|
0111500
|
2025-01-03
|
705 MIDDLE STREET, MIDDLETOWN, CT, 06457
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2025-01-03
|
Related Activity
Type |
Referral |
Activity Nr |
2248292 |
Safety |
Yes |
|
|
346801038
|
0111500
|
2023-06-29
|
701 MIDDLE STREET, MIDDLETOWN, CT, 06457
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-06-29
|
Emphasis |
N: AMPUTATE, L: FORKLIFT
|
Case Closed |
2023-10-12
|
Related Activity
Type |
Complaint |
Activity Nr |
2046261 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-09-01 |
Abatement Due Date |
2023-10-20 |
Current Penalty |
5581.0 |
Initial Penalty |
11162.0 |
Final Order |
2023-10-03 |
Nr Instances |
9 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips, and particles. WORKSHOP/WIRE ROOM: The ingoing nip point of Reel-O-Matic, Reel Power and Coiling machines were insufficiently guarded. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040041 A02 |
Issuance Date |
2023-09-01 |
Abatement Due Date |
2023-10-20 |
Current Penalty |
1116.0 |
Initial Penalty |
2232.0 |
Final Order |
2023-10-03 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.41(a)(2):29 CFR 1904.41(a)(2) Annual electronic submission of OSHA Form 300A Summary of Work-Related Injuries and Illnesses by establishments with 20 or more employees but fewer than 250 employees in designated industries. If your establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form. Located at the U.S. Electrical Services, Inc., 705 Middle Street, Middletown, CT 06457: On or about June 29, 2023, the employer had not electronically submitted information from their calendar year 2022 OSHA Form 300A or equivalent to the ITA database by March 2, 2023. a). The establishment employed 281 employees and is classified NAICS 423610 during calendar year 2022. |
|
|
344729876
|
0111500
|
2020-04-23
|
705 MIDDLE STREET, MIDDLETOWN, CT, 06457
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-06-30
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2020-08-13
|
Related Activity
Type |
Referral |
Activity Nr |
1577099 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2020-07-02 |
Abatement Due Date |
2020-08-19 |
Current Penalty |
6000.0 |
Initial Penalty |
8482.0 |
Final Order |
2020-07-31 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated; the person certifying that the evaluation had been performed; the date(s) of the hazard assessment; and, which identified the document as a certification of hazard assessment: WAREHOUSE/WORKSHOP: The employer had not verified through a written certification that the workplace hazard assessment for personal protective equipment (PPE) had been performed as complete. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19100178 L02 II |
Issuance Date |
2020-07-02 |
Abatement Due Date |
2020-08-19 |
Current Penalty |
6000.0 |
Initial Penalty |
8482.0 |
Final Order |
2020-07-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace: WAREHOUSE/WORKSHOP: The employer had not ensured through providing appropriate training so that the operator of the Raymond ACR 12 electrical pallet jack (PIT) was operating the PIT safely at all times. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19100178 L04 II B |
Issuance Date |
2020-07-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-07-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(ii)(B): Refresher training in relevant topics was not provided to the operator when operator had been involved in an accident or near-miss incident: WAREHOUSE/WORKSHOP: The employer had not conducted refresher training for the employee when the employee was observed conducting a near miss while operating the Raymond ACR 12 electrical pallet jack. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100178 P01 |
Issuance Date |
2020-07-02 |
Abatement Due Date |
2020-08-19 |
Current Penalty |
6000.0 |
Initial Penalty |
8482.0 |
Final Order |
2020-07-31 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): WAREHOUSE/WORKSHOP: The employer had not taken the Raymond ACR 12 electrical pallet jack out of service when the truck had been found defective and was still showing few error codes. |
|
|
340148949
|
0111500
|
2014-12-19
|
705 MIDDLE STREET, MIDDLETOWN, CT, 06457
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-12-19
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2015-05-28
|
Related Activity
Type |
Complaint |
Activity Nr |
926558 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19100178 P01 |
Issuance Date |
2015-02-18 |
Current Penalty |
220.0 |
Initial Penalty |
220.0 |
Final Order |
2015-03-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition. WAREHOUSE: The lights of the Yale powered industrial cherry picker were not operable. Electrical Wholesalers, Inc. was previously cited for a violation of this Occupational Safety and Health standard 29 CFR 1910.178(p)(1), which was contained in OSHA Inspection Number 315720334, Citation 1, Item Number 1a, issued on 11-04-2011, a final order date of 12-14-2011, with respect to a workplace location at 1935 Stratford Avenue, Stratford, CT 06615. ABATED DURING THE INSPECTION. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2015-02-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-03-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. WAREHOUSE/PRODUCT LOCATION LB-30A: The portable ABC fire extinguisher was blocked with plastic containers and a mop. ABATED DURING THE INSPECTION. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100178 L06 |
Issuance Date |
2015-02-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-03-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. WAREHOUSE: The employer did not ensure through a written certification that the powered industrial truck (PIT) operator had been trained and evaluated. ABATED DURING THE INSPECTION. |
|
|