Search icon

J.P. CUSANELLI HOME IMPROVEMENT INC

Company Details

Entity Name: J.P. CUSANELLI HOME IMPROVEMENT INC
Jurisdiction: Connecticut
Legal type: Stock
Citizenship: Domestic
Status: Forfeited
Date Formed: 03 Feb 2003
Business ALEI: 0738747
Business address: 31 MONROE RD, ENFIELD, CT, 06082
ZIP code: 06082
County: Hartford
Place of Formation: CONNECTICUT
Total authorized shares: 2000

Agent

Name Role Business address Residence address
JAMES CUSANELLI Agent 31 MONROE RD, ENFIELD, CT, 06082, United States 31 MONROE RD, ENFIELD, CT, 06082, United States

Officer

Name Role Business address Residence address
ADAM J. CUSANELLII Officer 31 MONROE RD, ENFIELD, CT, 06082, United States 12 MARSHALL DR, ENFIELD, CT, 06082, United States
JAMES P. CUSANELLI Officer 31 MONROE RD, ENFIELD, CT, 06082, United States 31 MONROE RD, ENFIELD, CT, 06082, United States
CAROL A. CUSANELLI Officer 31 MONROE RD, ENFIELD, CT, 06082, United States 31 MONROE RD, ENFIELD, CT, 06082, United States

Filing

Filing number Filing date Effective date Filing category Filing type Report year
0007368556 2021-06-10 No data Administrative Dissolution Certificate of Dissolution/Revocation No data
0007212937 2021-03-09 No data Administrative Dissolution Notice of Intent to Dissolve/Revoke No data
0002530843 2003-02-03 2003-02-03 First Report Organization and First Report No data
0002530842 2003-02-03 No data Business Formation Certificate of Incorporation No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339811515 0112000 2014-06-17 76 SPRING STREET, WINDSOR LOCKS, CT, 06096
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-06-17
Emphasis L: EISAOF, L: EISAX50, L: FALL, P: FALL
Case Closed 2014-10-17

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-10-31
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access were not provided with portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used. 76 Spring Street, Windsor Locks, CT 06096 on or about 06/17/2014: Employees were utilizing supporting ladders of a ladder jack scaffold to gain access to the scaffold platform, which required the employees to climb out and over the platform.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-10-31
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: 76 Spring Street, Windsor Locks, CT 06096 on or about 06/17/2014: An employee was not provided with personal fall protection system while utilizing ladder jack scaffold. The employee was exposed to 20 foot fall.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-07-22
Abatement Due Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-10-31
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) 76 Spring Street, Windsor Locks, CT 06096 on or about 06/17/2014: Employees were exposed to 23 foot fall hazard while engaged in roofing activities without utilizing any type of fall protection.

Date of last update: 17 Feb 2025

Sources: Connecticut's Official State Website