Entity Name: | INSTALLED BUILDING PRODUCTS, LLC |
Jurisdiction: | Connecticut |
Legal type: | LLC |
Citizenship: | Foreign |
Status: | Active |
Sub status: | Annual report due |
Date Formed: | 08 Mar 2002 |
Business ALEI: | 0707932 |
Annual report due: | 31 Mar 2026 |
NAICS code: | 238310 - Drywall and Insulation Contractors |
Business address: | 495 South High Street, Suite 50, Columbus, OH, 43215, United States |
Mailing address: | 495 South High Street, Suite 50, Columbus, OH, United States, 43215 |
Mailing jurisdiction address: | 495 SOUTH HIGH STREET SUITE 50, COLUMBUS, DE, 43215, United States |
Place of Formation: | DELAWARE |
E-Mail: | ibptaxdepartment@installed.net |
E-Mail: | pam.henson@installed.net |
Name | Role | Business address |
---|---|---|
IBP Holdings LLC | Officer | 495 South High Street, Suite 50, Columbus, OH, 43215, United States |
Name | Role |
---|---|
C T CORPORATION SYSTEM | Agent |
Filing number | Filing date | Effective date | Filing category | Filing type | Report year |
---|---|---|---|---|---|
BF-0013275141 | 2024-12-02 | No data | Mass Agent Change � Address | Agent Address Change | No data |
BF-0012222260 | 2024-03-29 | No data | Annual Report | Annual Report | No data |
BF-0011408709 | 2023-03-28 | No data | Annual Report | Annual Report | No data |
BF-0010294704 | 2022-03-11 | No data | Annual Report | Annual Report | 2022 |
0007216141 | 2021-03-10 | No data | Annual Report | Annual Report | 2021 |
0006846903 | 2020-03-24 | No data | Annual Report | Annual Report | 2020 |
0006463406 | 2019-03-14 | No data | Annual Report | Annual Report | 2019 |
0006113379 | 2018-03-08 | No data | Annual Report | Annual Report | 2018 |
0005783199 | 2017-03-06 | No data | Annual Report | Annual Report | 2017 |
0005508071 | 2016-03-08 | No data | Annual Report | Annual Report | 2016 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342683778 | 0111500 | 2017-10-05 | 56 CLAPBOARD RIDGE ROAD, GREENWICH, CT, 06830 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1269131 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-03-09 |
Current Penalty | 6300.0 |
Initial Penalty | 9054.0 |
Final Order | 2018-03-23 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): JOBSITE: The employee spraying insulation while standing on a 2 X 6 wooden plank was not protected from the hazard of falling between 9 feet and 13 feet to the lower level by the use of guardrails, personal fall arrest system or other equivalent means. On or about 9/29/17, the employee standing on the above wooden plank to perform the tasks tripped and fell between 9 feet and 13 feet to the lower level and sustained severe injury to the head and fractured the vertebrae from the incident. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2018-02-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: JOBSITE: The employees exposed to fall hazards of up to 13 feet above lower levels while spraying insulation were not trained in fall hazards and the procedures to be followed to minimize such hazards. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100134 F02 |
Issuance Date | 2018-02-27 |
Abatement Due Date | 2018-03-23 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-23 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(f)(2): Fit testing. The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. JOBSITE: The employees, wearing tight fitting full face mask respirators while performing spraying insulation activities had not received fit testing prior to initial use of the respirator and at least on an annual basis as required. |
Inspection Type | Prog Related |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-04-15 |
Emphasis | L: EISAOF, L: FALL, P: FALL |
Case Closed | 2015-06-10 |
Related Activity
Type | Inspection |
Activity Nr | 1055566 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B14 |
Issuance Date | 2015-04-24 |
Current Penalty | 1400.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-05-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. On or about 04/15/2015 employees at 659 Goodale Hill Road construction site were exposed to approximately 15' falls. Employees were engaged in insulation installation without fall protection. |