Entity Name: | DEHM DRYWALL LLC |
Jurisdiction: | Connecticut |
Legal type: | LLC |
Citizenship: | Domestic |
Status: | Active |
Sub status: | Annual report due |
Date Formed: | 17 Jan 1996 |
Business ALEI: | 0528864 |
Annual report due: | 31 Mar 2026 |
Business address: | 12 WHITEHALL PLACE, FARMINGTON, CT, 06032, United States |
Mailing address: | 12 WHITEHALL PLACE, FARMINGTON, CT, United States, 06032 |
ZIP code: | 06032 |
County: | Hartford |
Place of Formation: | CONNECTICUT |
E-Mail: | neilj54@comcast.net |
Certification Type: | SBE |
Class Description: | No minority race/ethnicity identified |
Woman Owned: | Not Identified as Women-Owned |
Disabled Owned: | Not disabled-owned |
Active Date: | 2019-10-30 |
Expiration Date: | 2021-10-30 |
Status: | Expired |
Product: | Metal framing, Drywall, Acoustical ceilings All work is subcontracted out. |
Goods And Services Description: | Building and Facility Construction and Maintenance Services |
NAICS
238310 Drywall and Insulation ContractorsThis industry comprises establishments primarily engaged in drywall, plaster work, and building insulation work. Plaster work includes applying plain or ornamental plaster, and installation of lath to receive plaster. The work performed may include new work, additions, alterations, maintenance, and repairs. Establishments primarily engaged in providing firestop services are included in this industry. Learn more at the U.S. Census Bureau
Name | Role | Business address | Mailing address | Phone | Residence address | |
---|---|---|---|---|---|---|
DEHM DRYWALL LLC | Agent | 12 WHITEHALL PLACE, FARMINGTON, CT, 06032, United States | 12 WHITEHALL PLACE, FARMINGTON, CT, 06032, United States | +1 860-670-1451 | neilj54@comcast.net | CONNECTICUT, 12 WHITEHALL PLACE, FARMINGTON, CT, 06032, United States |
Name | Role | Business address | Residence address |
---|---|---|---|
NEIL DEHM | Officer | 12 WHITEHALL PLACE, FARMINGTON, CT, 06032, United States | 12 WHITEHALL PLACE, FARMINGTON, CT, 06032, United States |
Filing number | Filing date | Effective date | Filing category | Filing type | Report year |
---|---|---|---|---|---|
BF-0012920042 | 2025-03-06 | - | Annual Report | Annual Report | - |
BF-0012388952 | 2024-02-27 | - | Annual Report | Annual Report | - |
BF-0011396376 | 2023-03-24 | - | Annual Report | Annual Report | - |
BF-0010277591 | 2022-03-15 | - | Annual Report | Annual Report | 2022 |
0007174454 | 2021-02-18 | - | Annual Report | Annual Report | 2021 |
0006838287 | 2020-03-17 | - | Annual Report | Annual Report | 2020 |
0006450071 | 2019-03-11 | - | Annual Report | Annual Report | 2018 |
0006450099 | 2019-03-11 | - | Annual Report | Annual Report | 2019 |
0005748311 | 2017-01-24 | - | Annual Report | Annual Report | 2017 |
0005514451 | 2016-03-15 | - | Annual Report | Annual Report | 2016 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339406035 | 0111500 | 2013-09-09 | 52 MISSIONARY ROAD, CROMWELL, CT, 06416 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 852490 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260451 E01 |
Issuance Date | 2013-11-27 |
Abatement Due Date | 2013-12-06 |
Current Penalty | 1200.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. WORKSITE: The employee, climbing the end frame of a mobile fabricated frame scaffold, was not provided with a portable ladder or other means of access to the working surface of the scaffold. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 F03 |
Issuance Date | 2013-11-27 |
Current Penalty | 2200.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. WORKSITE: The mobile fabricated frame scaffold, used by the employee to install drywall was not inspected by a competent person to ensure the scaffold was safe to use. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260452 W01 |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(w)(1): Scaffolds shall be braced by cross, horizontal, or diagonal braces, or combination thereof, to prevent racking or collapse of the scaffold and to secure vertical members together laterally so as to automatically square and align the vertical members. Scaffolds shall be plumb, level, and squared. All brace connections shall be secured. WORKSITE: The mobile fabricated frame scaffold, used by the employee to install drywall was not properly braced with cross bracing on either side of the scaffold. |
Citation ID | 01002C |
Citaton Type | Serious |
Standard Cited | 19260452 W09 |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(w)(9): Caster stems and wheel stems shall be pinned or otherwise secured in scaffold legs or adjustment screws. WORKSITE: The caster wheels on the mobile fabricated frame scaffold were not positively pinned or otherwise secured to the scaffold. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2013-11-27 |
Abatement Due Date | 2013-12-17 |
Current Penalty | 1400.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable: WORKSITE: The employee, installing drywall from a mobile fabricated frame scaffold was not provided training to recognize the hazards associated with the type of scaffolding being used or the procedures necessary to eliminate or minimize those hazards. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
7509048105 | 2020-07-23 | 0156 | PPP | 12 WHITEHALL PL, FARMINGTON, CT, 06032-1455 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
This table presents a concise summary of a company's liens and debts, detailing essential information such as the lien type, debt amount, associated parties, and current status of each financial obligation.
Subsequent Filing No | Status | Type | Filing Date | Lapse Date | Filing Type | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0005257209 | Active | OFS | 2024-12-17 | 2030-01-27 | AMENDMENT | |||||||||||||||||||
|
Name | SOVEREIGN BANK |
Role | Secured Party |
Name | SANTANDER BANK, N.A. |
Role | Secured Party |
Name | DEHM DRYWALL LLC |
Role | Debtor |
Parties
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SOVEREIGN BANK |
Role | Secured Party |
Name | Santander Bank, N.A. |
Role | Secured Party |
Parties
Name | SOVEREIGN BANK |
Role | Secured Party |
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SANTANDER BANK, N.A. |
Role | Secured Party |
Parties
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SOVEREIGN BANK |
Role | Secured Party |
Parties
Name | Santander Bank, N.A. |
Role | Secured Party |
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SOVEREIGN BANK |
Role | Secured Party |
Parties
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SOVEREIGN BANK |
Role | Secured Party |
Parties
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | U.S. SMALL BUSINESS ADMINISTRATION |
Role | Secured Party |
Parties
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SOVEREIGN BANK |
Role | Secured Party |
Parties
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SOVEREIGN BANK |
Role | Secured Party |
Parties
Name | DEHM DRYWALL LLC |
Role | Debtor |
Name | SOVEREIGN BANK |
Role | Secured Party |