Search icon

EAST COAST SENSORS, INCORPORATED

Date of last update: 21 Apr 2025. Data updated weekly.

Company Details

Entity Name: EAST COAST SENSORS, INCORPORATED
Jurisdiction: Connecticut
Legal type: Stock
Citizenship: Domestic
Status: Active
Sub status: Annual report past due
Date Formed: 26 Feb 1991
Business ALEI: 0258969
Annual report due: 26 Feb 2025
Business address: 20 HATHAWAY DR, STRATFORD, CT, 06615, United States
Mailing address: 20 HATHAWAY DR, STRATFORD, CT, United States, 06615
ZIP code: 06615
County: Fairfield
Place of Formation: CONNECTICUT
Total authorized shares: 10000
E-Mail: stefanie@ecsensors.com

Industry & Business Activity

NAICS

335999 All Other Miscellaneous Electrical Equipment and Component Manufacturing

This U.S. industry comprises establishments primarily engaged in manufacturing industrial and commercial electric apparatus and other equipment (except lighting equipment, household appliances, transformers, motors, generators, switchgear, relays, industrial controls, batteries, communication and energy wire and cable, wiring devices, and carbon and graphite products). Examples of products made by these establishments are power converters (i.e., AC to DC and DC to AC), power supplies, surge suppressors, and similar equipment for industrial-type and consumer-type equipment. Learn more at the U.S. Census Bureau

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
6JJ81 Active U.S./Canada Manufacturer 2011-09-20 2024-03-09 2026-05-27 2022-06-24

Contact Information

POC GARY F. HEID
Phone +1 800-722-4592
Fax +1 203-381-6278
Address 20 HATHAWAY DR, STRATFORD, CT, 06615 7369, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

Officer

Name Role Business address Phone E-Mail Residence address
SANDRA C. HEID Officer 20 HATHAWAY DR, STRATFORD, CT, 06615, United States - - 10 COPPER MILL ROAD, MONROE, CT, 06468, United States
GARY F. HEID Officer 20 HATHAWAY DR, STRATFORD, CT, 06615, United States +1 203-218-0759 stefanie@ecsensors.com 10 COPPER MILL ROAD, MONROE, CT, 06468, United States
GARY A. HEID Officer 20 HATHAWAY DR, STRATFORD, CT, 06615, United States - - 32 BRAELOCH WAY, MONROE, CT, 06468, United States

Agent

Name Role Business address Mailing address Phone E-Mail Residence address
GARY F. HEID Agent 20 HATHAWAY DRIVE, STRATFORD, CT, 06615, United States 20 HATHAWAY DRIVE, STRATFORD, CT, 06615, United States +1 203-218-0759 stefanie@ecsensors.com 10 COPPER MILL ROAD, MONROE, CT, 06468, United States

Filing

Filing number Filing date Effective date Filing category Filing type Report year
BF-0012268355 2024-02-23 - Annual Report Annual Report -
BF-0009805673 2023-08-18 - Annual Report Annual Report -
BF-0011391458 2023-08-18 - Annual Report Annual Report -
BF-0010858364 2023-08-18 - Annual Report Annual Report -
BF-0011918963 2023-08-07 - Administrative Dissolution Notice of Intent to Dissolve/Revoke -
0006831235 2020-03-13 - Annual Report Annual Report 2020
0006731062 2020-01-23 - Annual Report Annual Report 2019
0006731058 2020-01-23 - Annual Report Annual Report 2018
0006641008 2019-09-04 2019-09-04 Amendment Amend -
0005753132 2017-01-30 - Change of Email Address Business Email Address Change -

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341193712 0111500 2016-01-13 20 HATHAWAY DRIVE, STRATFORD, CT, 06615
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2016-01-13
Emphasis N: AMPUTATE
Case Closed 2016-12-19

Related Activity

Type Inspection
Activity Nr 1037337
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2016-05-31
Abatement Due Date 2016-06-08
Current Penalty 1200.0
Initial Penalty 1600.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. Blasting Machine Area: Blasting agent left on the floor created slip, trip and/or a fall hazard.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2016-05-31
Abatement Due Date 2016-09-19
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Workshop: A written and implemented respiratory protection program was not established for each employee required to wear N95 filtering face pieces while performing tasks such as (but not limited to) working with silver flux, potting, and welding.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 C02 I
Issuance Date 2016-05-31
Abatement Due Date 2016-09-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): The employer did not determine if the voluntary use of a respirator did not in itself create a hazard: Workshop: A determination as to whether the use of N95 filtering face piece respirators created a hazard itself was not determined.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100134 D01
Issuance Date 2016-05-31
Abatement Due Date 2016-09-19
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1): The employer did not select and provide an appropriate respirator based on the respiratory hazard(s) to which the worker was exposed. Workshop: The appropriate respirator was not selected and provided for each employee exposed to dust, fumes, and/or vapors.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19100134 D01 II
Issuance Date 2016-05-31
Abatement Due Date 2016-09-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification: Workshop: NIOSH-certified respirators were not selected and used for each employee working with chemicals and/or chemical vapors from products such as (but not limited to) epoxies and flux .
Citation ID 01002E
Citaton Type Serious
Standard Cited 19100134 D01 III
Issuance Date 2016-05-31
Abatement Due Date 2016-09-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: Workshop: An identification and evaluation along with a reasonable estimate of employee exposure of all respiratory hazards for each product and chemical used in tasks such as (but not limited to) silver solder, flux brazing, blasting, assembly, potting ,and working with epoxies was not conducted.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100212 B
Issuance Date 2016-05-31
Abatement Due Date 2016-07-01
Current Penalty 1200.0
Initial Penalty 1600.0
Final Order 2016-06-23
Nr Instances 3
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: Workshop: The following bench grinders used to sharpen parts were not mounted to a table or similar fixed object to prevent walking and moving. 1. The Jet 6" bench grinder model JBG-6A Serial Number 07050838 2. The Dayton 6 bench grinder model 4Z672D Lot no: 200111 3. The Jet 6 bench grinder model JBG-6A Serial Number 08040615
Citation ID 01005
Citaton Type Serious
Standard Cited 19100215 A02
Issuance Date 2016-05-31
Abatement Due Date 2016-06-08
Current Penalty 1200.0
Initial Penalty 1600.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: Workshop: The Ryobi 6" bench grinder used to sharpen tools and to clean parts was missing the side cover(safety guard) to cover the spindle end, nut and flange.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2016-05-31
Abatement Due Date 2016-06-10
Current Penalty 1800.0
Initial Penalty 2400.0
Final Order 2016-06-23
Nr Instances 5
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Workshop: The work rests on the following 6" bench grinders used to perform tasks such as (but not limited to) cleaning parts and cutting were adjusted to more than 1/8th inch. 3. The Ryobi 6" bench grinder model BGH6110 5. The Jet 6" bench grinder model BDG-6A serial number 14061424
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2016-05-31
Abatement Due Date 2016-06-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-06-23
Nr Instances 5
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Workshop: The tongue guards on the following 6" bench grinders were adjusted over one fourth inch: 3. The Ryobi 6" bench grinder model BGH6110 5. The Jet 6" bench grinder model BDG-6A serial number 14061424
Citation ID 01007
Citaton Type Serious
Standard Cited 19100253 B02 I
Issuance Date 2016-05-31
Abatement Due Date 2016-06-08
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(2)(i): Compressed gas cylinders were not kept away from radiators and other sources of heat: Welding Area: The oxygen and acetylene compressed gas cylinders were stored near the area where welding with open flames was being performed.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2016-05-31
Abatement Due Date 2016-07-18
Current Penalty 1000.0
Initial Penalty 3200.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 17
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date of the hazard assessment; and which identifies the document as a certification of hazard assessment. Workshop: The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date of the hazard assessment; and which identifies the document as a certification of hazard assessment.
Citation ID 02002A
Citaton Type Repeat
Standard Cited 19101200 H01
Issuance Date 2016-05-31
Abatement Due Date 2016-07-18
Current Penalty 2800.0
Initial Penalty 3200.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 17
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and material safety data sheets. Workshop: Each employees required to work and handle chemicals such as (but not limited to) flux, potting cement, epoxy, and blasting agent were not provided with information and training on the hazardous products and chemicals at the time of their initial assignment and whenever a new hazard was introduced into the work area. East Coast Sensors, Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(h)(1), which was contained in OSHA inspection number 1037337, citation number 01, item number 002b and was affirmed as a final order on May 6, 2015, with respect to a workplace located at 20 Hathaway Drive, Stratford, CT
Citation ID 02002B
Citaton Type Repeat
Standard Cited 19101200 E01
Issuance Date 2016-05-31
Abatement Due Date 2016-07-18
Current Penalty 0.0
Initial Penalty 800.0
Final Order 2016-06-23
Nr Instances 1
Nr Exposed 17
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Workshop: The written hazard communication program did not include all the required criteria specified in 29 CFR1910.1200(f), (g) and (h) in that topics such as but not limited to pictograms, signal words, product identification, hazard statements, precautionary statements were missing. East Coast Sensors Incorporated was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(e)(1), which was contained in OSHA inspection number 1037337, citation number 01, item number 002a and was affirmed as a final order on May 6, 2015, with respect to a workplace located at 20 Hathaway Drive, Stratford, CT

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
5220287710 2020-05-03 0156 PPP 20 HATHAWAY DR, STRATFORD, CT, 06615-7304
Loan Status Date 2021-03-17
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 330527
Loan Approval Amount (current) 330527
Undisbursed Amount 0
Franchise Name -
Lender Location ID 9551
Servicing Lender Name Bank of America, National Association
Servicing Lender Address 100 N Tryon St, Ste 170, CHARLOTTE, NC, 28202-4024
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description New Business or 2 years or less
Project Address STRATFORD, FAIRFIELD, CT, 06615-7304
Project Congressional District CT-03
Number of Employees 23
NAICS code 334513
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 9551
Originating Lender Name Bank of America, National Association
Originating Lender Address CHARLOTTE, NC
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 333080.66
Forgiveness Paid Date 2021-02-11
See something incorrect or outdated? Let us know

Sources: Company Profile on Connecticut's Official State Website

* While we strive to keep this information correct and up-to-date, it is not the primary source, and the dataset source should always be referred to for definitive information