345057814
|
0112000
|
2020-12-09
|
585 PARK STREET, HARTFORD, CT, 06101
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-02-23
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2021-06-09
|
Related Activity
Type |
Referral |
Activity Nr |
1702989 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2021-04-13 |
Current Penalty |
13653.0 |
Initial Penalty |
13653.0 |
Final Order |
2021-05-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1):Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut. On or about 12/09/2020 employees at the Hartford Public Library foundation project were exposed to amputation hazards from an unguarded rotating table saw blade. Employees were operating a Craftsman table saw with no blade guard assembly. |
|
|
341717890
|
0111500
|
2016-03-02
|
1 GREENWICH PLACE, SHELTON, CT, 06484
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-08-23
|
Case Closed |
2016-09-02
|
Related Activity
Type |
Inspection |
Activity Nr |
1171784 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171913 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171916 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171924 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171930 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171936 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171775 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1151617 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1169486 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1165623 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1130019 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1144554 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1171920 |
Health |
Yes |
|
|
340848936
|
0112000
|
2015-08-14
|
XL CENTER- VETERANS MEMORIAL COLISEUM CHURCH STREET, HARTFORD, CT, 06103
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-08-14
|
Emphasis |
N: SILICA, L: SILICA, L: EISAX50, L: R1NOISE
|
Case Closed |
2016-01-25
|
Related Activity
Type |
Referral |
Activity Nr |
1010837 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2015-09-21 |
Abatement Due Date |
2015-11-06 |
Current Penalty |
1750.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-10-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103) XL Center-Veteran's Memorial Coliseum, Church Street On or about 8/14/15, a written respiratory protection program was not established and implemented for the required use of N95 filtering facepiece respirators during dry demolition of concrete using a jackhammer. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2015-09-21 |
Abatement Due Date |
2015-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103) XL Center- Veteran's Memorial Coliseum, Church Street On or about 8/14/15, an employee required to wear an N95 filtering facepiece respirator had not been provided a medical evaluation to determine his ability to use it safely. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 F01 |
Issuance Date |
2015-09-21 |
Abatement Due Date |
2015-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction Reference 1926.103) XL Center - Veteran's Memorial Coliseum On or about 8/14/15, an employee that was required to wear an N95 filtering facepiece respirator was not required to take and pass a fit test for the respirator used. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100134 K |
Issuance Date |
2015-09-21 |
Abatement Due Date |
2015-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: (Construction Reference 1926.103) XL Center - Veteran's Memorial Coliseum, Church Street On or about 8/14/15, an employee that was required to wear an N95 filter facepiece respirator without having been provided comprehensive, understandable training. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2015-09-21 |
Abatement Due Date |
2015-11-06 |
Current Penalty |
1750.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-10-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) XL Center - Veterans Memorial Coliseum; Church St., Hartford, CT On or about 8/14/15, the employer did not have a written hazard communication program. Employees were performing demolition work, exposing them to silica. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2015-09-21 |
Abatement Due Date |
2015-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) XL Center - Veterans Memorial Coliseum; Church St., Hartford, CT On or about 8/14/15, employees demolishing concrete stairs, containing silica, had not received hazard communication training. |
|
|
311758528
|
0112000
|
2008-06-16
|
151 FARMINGTON AVENUE, HARTFORD, CT, 06103
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-06-16
|
Case Closed |
2008-06-16
|
Related Activity
Type |
Referral |
Activity Nr |
200089423 |
Safety |
Yes |
|
|
311754774
|
0112000
|
2008-01-23
|
300 WINDSOR STREET, HARTFORD, CT, 06103
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-01-23
|
Emphasis |
S: COMMERCIAL CONSTR
|
Case Closed |
2008-02-06
|
Related Activity
Type |
Referral |
Activity Nr |
200088953 |
Safety |
Yes |
|
|
116137365
|
0112000
|
1997-01-30
|
J.C. PENNEY, 600 WESTFARMS MALL, FARMINGTON, CT, 06032
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
1997-02-26
|
Emphasis |
L: ASBESTOS
|
Case Closed |
1998-05-18
|
Related Activity
Type |
Complaint |
Activity Nr |
75042564 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
116137357 |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19261101 E01 |
Issuance Date |
1997-07-08 |
Abatement Due Date |
1997-07-14 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
3 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261101 G08 I |
Issuance Date |
1997-07-08 |
Abatement Due Date |
1997-07-14 |
Nr Instances |
3 |
Nr Exposed |
12 |
Gravity |
03 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261101 H02 IV |
Issuance Date |
1997-07-08 |
Abatement Due Date |
1997-07-14 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
3 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261101 I01 |
Issuance Date |
1997-07-08 |
Abatement Due Date |
1997-07-14 |
Nr Instances |
3 |
Nr Exposed |
12 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261101 K09 I |
Issuance Date |
1997-07-08 |
Abatement Due Date |
1997-08-22 |
Current Penalty |
375.0 |
Initial Penalty |
750.0 |
Nr Instances |
12 |
Nr Exposed |
100 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
1997-07-08 |
Abatement Due Date |
1997-08-22 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
01 |
|
|