Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-05-30
|
Emphasis |
L: FORKLIFT, N: HEATNEP
|
Related Activity
Type |
Complaint |
Activity Nr |
2167461 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A02 |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
2420.0 |
Initial Penalty |
9680.0 |
Final Order |
2024-10-10 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(2):29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided. Establishment: On or about May 30, 2024, the employer did not ensure that all work areas including but not limited to wet process rooms one and two were kept free of standing water by the use of an adequate drainage system. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
2016.75 |
Initial Penalty |
8067.0 |
Final Order |
2024-10-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Establishment: On or about May 30, 2024, the employer did not ensure that all employees who were required to operate forklifts in the warehouse were competent to operate such vehicles safely, through the completion of a training program. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100178 Q01 |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
8067.0 |
Final Order |
2024-10-10 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(1):Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel. Establishment: On or about May 30, 2024, the employer did not ensure that forklifts that were equipped with inoperative horns and operated in the warehouse were removed from service until repairs were made. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
2823.0 |
Initial Penalty |
11292.0 |
Final Order |
2024-10-10 |
Nr Instances |
6 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Establishment: On or about May 30, 2024, the employer did not ensure that food processing and sanitizing machines with rotating parts such as pulleys or chains located in rooms one, two and three, were equipped with covers to protect workers who worked near such machines. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
2016.75 |
Initial Penalty |
8067.0 |
Final Order |
2024-10-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i) Establishment: On or about May 30, 2024, the employer did not ensure that live parts operating at 230 volts were guarded against employee contact in that employees were required to bypass a protective cabinet door in order to operate the "dice" machine. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040041 A01 I |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
403.25 |
Initial Penalty |
1613.0 |
Final Order |
2024-10-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.41(a)(1)(i):The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date. Establishment: On or about May 30, 2024, the employer who has 44 employees, did not ensure that information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses was electronically submitted to OSHA. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-10-10 |
Nr Instances |
1 |
Nr Exposed |
8 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2). Establishment: On or about May 30, 2024, the employer did not ensure that a written hazard assessment for personal protective equipment (PPE) was completed for employees who were required to handle food grade acid. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100178 L04 III |
Issuance Date |
2024-09-18 |
Abatement Due Date |
2024-11-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-10-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii):An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years. Establishment: On or about May 30, 2024, the employer did not ensure that all employees who were required to operate forklifts in the warehouse were evaluated for performance at least every three years. |
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-06-08
|
Emphasis |
L: FORKLIFT, L: EISAOF
|
Case Closed |
2016-07-15
|
Related Activity
Type |
Complaint |
Activity Nr |
1091819 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 II E |
Issuance Date |
2016-06-17 |
Abatement Due Date |
2016-08-04 |
Current Penalty |
2100.0 |
Initial Penalty |
3500.0 |
Final Order |
2016-07-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(ii)(E): Refresher training, including an evaluation of the effectiveness of that training shall be conducted when a condition in the workplace changes in a manner that could affect safe operation of the truck: WORKSHOP: The powered industrial truck (PIT) operator, who had operated a PIT from a previous employer was not provided with refresher training and an evaluation. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2016-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-14 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition. WORKSHOP: The employer had not marked the Mitsubishi powered industrial truck (PIT) as, "Out-Of-Service" or similar wording when the PIT had not operated. ABATED DURING THE INSPECTION |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 B01 |
Issuance Date |
2016-06-17 |
Abatement Due Date |
2016-06-29 |
Current Penalty |
400.0 |
Initial Penalty |
700.0 |
Final Order |
2016-07-14 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.29(b)(1): 29 CFR 1904.29(b)(1): The OSHA 300 log of work-related injuries and illnesses, 300A summaries, and first report of injuries were not completed in detail. ESTABLISHMENT: The employer had not completed the OSHA 300 log of Work-Related Injuries and Illnesses for the 2016 year in detail. Case #2, marked in Column (I) job transfer or restriction; no entry in Column (L) for the number of days job transfer or restriction. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2016-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-14 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. WORKSHOP: The employer did not verify through a written certification and an evaluation that the Workplace Hazard Assessment for personal protective equipment (PPE) had been completed as required. ABATED DURING THE INSPECTION |
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-06-08
|
Emphasis |
L: EISAOF, L: FORKLIFT
|
Case Closed |
2016-07-15
|
Related Activity
Type |
Complaint |
Activity Nr |
1091819 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 F02 |
Issuance Date |
2016-06-17 |
Current Penalty |
2000.0 |
Initial Penalty |
3500.0 |
Final Order |
2016-07-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(f)(2): The storage and handling of liquefied petroleum gas fuel shall be in accordance with NFPA Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58-1969), which is incorporated by reference as specified in Sec. 1910.6. WAREHOUSE: The right clamp on the propane tank of the Clark powered industrial truck (PIT) was held together with a buggie cord. ABATED DURING THE INSPECTION |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 P01 |
Issuance Date |
2016-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition. WAREHOUSE: The right light fixture of the No. 3 Toyota powered industrial truck (PIT) was missing the light. ABATED DURING THE INSPECTION |
|
|