Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-08-06 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling out of bad being struck by other vehicles: WORKPLACE: The Employer did not ensure through providing additional training, instruction, and visual observation that the powered industrial truck operators were utilizing seatbelts, at all times while operating the powered industrial forkllift trucks. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1640.0 |
Initial Penalty |
2400.0 |
Final Order |
2013-08-06 |
Nr Instances |
3 |
Nr Exposed |
10 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. The walking/working surfaces in and around the following machines had a lot of debris accumulated: 1. The Strip Tec wire stripping machine; large amounts of wires. 2. The Constellation hydraulic shear; an excessive accumulation of debris. 3. The baler machines; excessive accumulations of debris. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100022 D01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent. FACILITY: The Employer did not mark or post the load rating for the storage loft above the office. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100024 C |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.24(c): "Stair strength." Fixed stairways shall be designed and constructed to carry a load of five times the normal live load anticipated but never of less strength than to carry safely a moving concentrated load of 1,000 pounds. FACILITY: The stairs leading to the storage area above the office were damaged by forklifts pushing excessive accumulation of materials such as (but not limited to) bundles of wiring to be processed. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100023 D01 IV |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(d)(1)(iv): On stairways more than 44 inches wide but less than 88 inches wide, one handrail on each enclosed side and one stair railing on each open side. FACILITY: The stairs leading to the storage area above the office were not provided with handrails on either of the open sides. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100023 A01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(a)(1): Every stairway floor opening shall be guarded by a standard railing constructed in accordance with paragraph (e) of this section. The railing shall be provided on all exposed sides (except at entrance to stairway). For infrequently used stairways where traffic across the opening prevents the use of fixed standard railing (as when located in aisle spaces, etc.), the guard shall consist of a hinged floor opening cover of standard strength and construction and removable standard railings on all exposed sides (except at entrance to stairway). FACILITY: The stairway opening on the storage loft above the office was not protected by a guardrail system or equivalent, exposing employees to an 8'-10" fall. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. FACILITY: The edge of the storage area above the office was not protected by a guardrail system, exposing employees to an 8'-10" fall to the floor below. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100038 C |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-08-06 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.38(c): Minimum elements of an emergency action plan. An emergency action plan must include at a minimum: Procedures for reporting a fire or other emergency; Procedures for emergency evacuation, including type of evacuation and exit route assignments; Procedures to account for all employees after evacuation: FACILITY: The Employers written Emergency Evacuation plan was generic and did not include workplace specific procedures for the following: - Procedures for reporting a fire or other emergency. - Procedures for the type of emergency evacuation and exit route assignments. - Procedures to account for all employees after the evacuation. - The name or job title of every member who may be contacted by employees who need more information about the plan or an explanation of their duties under the plan. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100039 C05 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-08-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.39(c): Minimum elements of a fire prevention plan. A fire prevention plan must include: A list of all major fire hazards, proper handling and storage procedures for hazardous materials, potential ignition sources and their control, and the type of fire protection equipment necessary to control each major hazard; Procedures to control accumulations of flammable and combustible waste materials; Procedures for regular maintenance of safeguards installed on heat-producing equipment to prevent the accidental ignition of combustible materials; The name or job title of employees responsible for maintaining equipment to prevent or control sources of ignition of fires; and The name or job title of employees responsible fo the control of fuel source hazards. FACILITY: The Employers written Fire Prevention plan was generic and did not include workplace specific procedures for the following: - A list of all major fire hazards, proper handling of and storage procedures for hazardous materials, potential ignition sources and their control, and the type of fire protection equipment necessary to control each major hazard. - The name or job title of employees responsible for maintaining equipment to prevent or control sources of ignition or fires. - The name or job title of employees responsible for the control of fuel source hazards. |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100038 F |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.38(f): Review of emergency action plan. An employer must review the emergency action plan with each employee covered by the plan; When the plan is developed or the employee is assigned initially to a job; When the employee's responsibilities under the plan change; and When the plan is changed. WORKPLACE: The Employer did not review the Emergency action plan with employees. |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100039 D |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.39(d): Employee information. An employer must inform employees upon initial assignment to a job of the fire hazards to which they are exposed. An employer must also review with each employee those parts of the fire prevention plan necessary for self-protection. WORKPLACE: The Employer did not review the Fire Prevention plan with employees. |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19100141 B01 III |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1640.0 |
Initial Penalty |
2400.0 |
Final Order |
2013-08-06 |
Nr Instances |
2 |
Nr Exposed |
18 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(b)(1)(iii): Portable drinking water dispensers shall be designed, constructed, and serviced so that sanitary conditions are maintained, shall be capable of being closed, and shall be equipped with a tap. FACILITY: The Employer did not ensure that the drinking water station was maintained in a sanitary condition. |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19100141 D01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
2 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(d)(1): General. Washing facilities shall be maintained in a sanitary condition. FACILITY: The Employer did not ensure that the washing facilities in both bathrooms were maintained in a sanitary condition. |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100141 G02 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
10 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.141(g)(2): Eating and drinking areas. No employee shall be allowed to consume food or beverages in a toilet room nor in any area exposed to a toxic material. FACILITY: The Employer allowed food and beverages to be consumed in the workplace where employees were exposed to hazardous materials such as (but not limited to) old lead acid batteries and radiators which may contain lead. |
|
Citation ID |
01010A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. FACILITY: The Employer did not establish and implement written machine specific step-by-step hazardous energy control procedures for employees during the maintenance and servicing of equipment including (but not limited to) the Compacting/Bailer machines and the Constellation Hydraulic shear. |
|
Citation ID |
01010B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: FACILITY: The employees, as authorized, affected and other types were not provided with information and training on the hazardous energy control lockout/tagout procedures during the servicing and maintenance of equipment such as (but not limited to) the Compacting/Baler machines adn the Constellation Hydraulic Shear. |
|
Citation ID |
01011A |
Citaton Type |
Serious |
Standard Cited |
19100157 C01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-31 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-08-06 |
Nr Instances |
12 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. FACILITY: The fire extinguishers located in the following areas were not mounted, located, or identified: A. Nine (9) fire extinguishers located under the scales desk. B. A Badger Nitrogen Compressed fire extinguisher located outside the office. C. A General ABC fire extinguisher located next to the stair to the storage area over the office. D. An Amerex ABC fire extinguisher located in the loading dock scales area. |
|
Citation ID |
01011B |
Citaton Type |
Serious |
Standard Cited |
19100157 C04 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
12 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(4): The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times. FACILITY: The Employer did not ensure that the following fire extinguishers were maintained in a fully charged and operational condition: 1. A General ABC fire extinguisher located next to the stair to the storage area over the office. 2. An Amerex ABC fire extinguisher located in the loading dock scales area. |
|
Citation ID |
01012A |
Citaton Type |
Serious |
Standard Cited |
19100157 E02 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-31 |
Current Penalty |
840.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-08-06 |
Nr Instances |
12 |
Nr Exposed |
18 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(e)(2): Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly. FACILITY: The Employer did not ensure that the fire extinguishers throughout the facility were visually inspected on a monthly basis. |
|
Citation ID |
01012B |
Citaton Type |
Serious |
Standard Cited |
19100157 E03 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
12 |
Nr Exposed |
18 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(e)(3): The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request. FACILITY: The Employer did not ensure that the fire extinguishers were subjected to annual maintenance checks. |
|
Citation ID |
01012C |
Citaton Type |
Serious |
Standard Cited |
19100157 F02 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(f)(2): The employer shall assure that portable extinguishers are hydrostatically tested at the intervals listed in Table L-1 of this section: FACILITY: The Employer did not ensure that the Amerex ABC dry chemical fire extinguisher located in the loading dock scales area was hydrostatically tested on a regular basis. |
|
Citation ID |
01013 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-08-06 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-08-06 |
Nr Instances |
8 |
Nr Exposed |
10 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. FACILITY: The employees operating the following machines were not adequately protected against catch points. These include (but are not limited to): 1. Rigby, model RB75 baler machine, serial number 84191 was missing the upper gate. 2. Baler machine; located between the HD 2200 and the Philadelphia model 2300 HD 14, no name or data plate. 3. Philadelphia Tracrail Baler; model 2300 HD 14, serial number 97T3924. 4. American Baler; no data plate. 5. Selco Baler; model V5-HD, serial number 04882534. 6. National Compactor Baler; model 3P-60, serial number A3-277-LLC. 7. Excel Baler; model HV10, serial number HV1090. 8. The out-feed cover of the Strip Tec Wire Stripping machine, no serial numbers was secured in the open position, exposing the operator to the rotating blades. |
|
Citation ID |
01014 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-08-06 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. FACILITY: The point of operation on the Constellation hydraulic shear, serial number E8403 was unguarded. |
|
Citation ID |
01015A |
Citaton Type |
Serious |
Standard Cited |
19100253 B01 III |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(1)(iii): Compressed gas cylinders shall be equipped with connections complying with the American National Standard Compressed Gas Cylinder Valve Outlet and Inlet Connections, ANSI B57.1-1965, which is incorporated by reference as specified in Sec. 1910.6. FACILITY: The gauge on the oxygen tank, used by employees during oxygen-fuel gas cutting operations was damaged. |
|
Citation ID |
01015B |
Citaton Type |
Serious |
Standard Cited |
19100253 B02 II |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards. FACILITY: An oxygen tank was left free standing in the area of the oxygen storage cage. |
|
Citation ID |
01016 |
Citaton Type |
Serious |
Standard Cited |
19100253 B05 II G |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-08-06 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(5)(ii)(G): Cylinder valves shall be closed when work is finished. FACILITY: The valves on the oxygen and propylene tanks used by employees during oxygen-fuel gas cutting operations were both left open while the unit were not in use. |
|
Citation ID |
01017 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-24 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
5 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. FACILITY: Five (5) Circuit breakers located above a work bench near the side overhead door were not marked to indicate their purpose. |
|
Citation ID |
01018A |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. FACILITY: The control box on the Strip Tec wire stripping machine had an unused opening that was not closed. |
|
Citation ID |
01018B |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means: FACILITY: A circuit breaker box located above a work bench and near the side overhead door was missing the cover, exposing live internal terminals. |
|
Citation ID |
01019 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-22 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. FACILITY: The outer sheathing of the power cord energizing the Strip Tec wire stripping machine, no serial number, was pulled away from the fitting, putting tension on the internal wiring and terminals. |
|
Citation ID |
01020A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 I |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1)(i): A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas). FACILITY: The Employers Hazard Communication program did not include a chemical inventory of the chemicals used in the workplace. |
|
Citation ID |
01020B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
2 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use. FACILITY: The Employer did not have a material safety data sheet for each chemical used by employees in the workplace which include (but is not limited to), oxygen and propylene. |
|
Citation ID |
01020C |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.) FACILITY: The Employer did not ensure that material safety data sheets for chemicals used in the workplace were readily available to employees. |
|
Citation ID |
01020D |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-09-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
18 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. FACILITY: Where employees were working with chemicals in the workplace which include, (but is not limited to) propane, gasoline, oxygen, and propylene, the Employer did not provided employees with information and training. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040033 A |
Issuance Date |
2013-07-12 |
Abatement Due Date |
2013-07-31 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Final Order |
2013-08-06 |
Nr Instances |
4 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.33(a): Basic requirement. You must save the OSHA 300 Log, the privacy case list (if one exists), the annual summary, and the OSHA 301 Incident Report forms for five (5) years following the end of the calendar year that these records cover. WORKPLACE: The Employer did not maintain the OSHA 301 Incident Reports or equivalent forms where recordable injuries had occured for five (5) years for the following years: 1. 2012 2. 2011 3: 2010 4. 2009 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100132 E |
Issuance Date |
2013-07-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(e): Defective and damaged equipment. Defective or damaged personal protective equipment shall not be used. FACILITY: An employee was wearing a hardhat with a broken suspension system. |
|